Part Number: 72-9027-xxx (xxx denotes gas)

Clip Disposable

The BW Clip single-gas detector is the most user friendly, reliable and cost effective way to ensure safety, compliance and productivity.

List of Benefits

  • Maintenance free!
  • Compact and light weight
  • Hibernation mode to extend life once used
  • Wide angle flash

 

It operates up to three years maintenance-free: Just turn the device on and let it run continuously no need for calibration, sensor replacement, battery replacement or battery charging. This means great reliability and no downtime. Don’t use your unit that often? With the two-year BW Clip for H2S or CO, you can put the device in a hibernation case when you’re not using it for a week or more effectively extending its life by that period of time. Great for turnarounds, short-term projects or employee leave. The BW Clip uses advanced technology for safety, compliance and productivity.

It uses SureCell, a unique dual reservoir sensor which dramatically improves performance, response time, and longevity compared to traditional electrochemical sensors and consistently delivers reliable instrument performance under the harshest of conditions.

Compatible with both the MicroDock II and the IntelliDoX instrument management system, the BW Clip ensures easy and accurate record keeping to keep you compliant. Not only is the IntelliDox the fastest bump test in the industry but it allows configuration of alarm set points and maximum productivity by performing different tests for up to five BW clip units at once!

Configurable Options

  • Configuration of high and low alarm set points before the device is activated.
  • Adjustment of alarm set points and other parameters as needed.
  • Option to display gas reading during alarm.
  • User settable bump test reminder.
  • Option to display the Real Time Clock.
SpecificationDetail Description
Size 4.1 x 5 x 8.7 cm / 1.6 x 2 x 3.4 in.
Weight 92g / 3.2 oz.
Temperature
H2S -40 to +50°C / -40 to +122°F
CO -30 to +50°C / -22 to +122°F
O2 -20 to +50°C / -4 to +122°F
SO2 -30 to +50°C / -22 to +122°F
Humidity 5% - 95% RH (non-condensing)
Alarms Visual, vibrating, audible (95dB) Low, High, Tests Activated detectors automatically perform one internal diagnostic test every 24 hours
Typical battery life Two years (H2S, CO, O2 or SO2), Three years (H2S or CO)
Event logging 35 most recent events
Ingress Protection IP 66/67
Certifications and approvals Class I, Div.1, Gr. A, B, C, D, Class I, Zone 0, Gr.IIC, ATEX
Warranty Two or three years from activation (given normal operation), plus one year shelf life (6 months for O2). Up to three years for two year H2S and CO detectors when used with the hibernation feature, limited to 24 months of detector operation.
 

Share this