Hydrogen cyanide

NO.12H
HCN
Performance
Measuring Range 0.05 to 1.6%
Number of Pump Strokes 1
Correction Factor 1
Sampling Time 1 minute per pump stroke
Detecting Limit 0.005% (n=1)
Colour Change Yellow → White
Reaction Principle HCN+Na2Pd(SO3)2 → White reaction product
Coefficient of Variation 10% (for 0.05 to 0.4 %), 5% (for 0.4 to 2 %)
Shelf Life 3 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Carbon monoxide   + Dark brown
Hydrogen sulphide   + Dark brown
Ethylene   + Dark brown
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
- C 4.7 ppm 5.6 to 40 %


Return to previous viewGo to top of page