Ethylene

NO.172
CH2¡§CH2
Performance
Measuring Range (25) to 800 ppm
Number of Pump Strokes 1
Correction Factor 1
Sampling Time 3 minutes per pump stroke
Detecting Limit 5 ppm (n=1)
Colour Change Pale yellow → Blue
Reaction Principle CH2:CH2 + (NH4)2MoO4 + PbSO4O → Molybdenum blue
Coefficient of Variation 10% (for 25 to 200 ppm), 5% (for 200 to 800 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Unnecessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Ammonia, Hydrogen cyanide   + White
Carbon monoxide, Hydrogen   + Blue (whole layer)
Hydrogen chloride   + Pink
Hydrogen sulphide   + Black
Butadiene   + White
Butane, Pentane   + Blue (whole layer)
Butylene, Propylene 1/4 + Blue
Other substance measurable with this detector tube
Substance Correction Factor No. of pump strokes Measuring Range
Acetylene 1.3 1 32.5 to 1040 ppm
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
200ppm - 2.7 to 36%