testo 325-I is the introduction to affordable flue gas analysis for SO2. It combines precision with user-friendly operation and low costs. It is the ideal instrument for checking emissions and monitoring thermal processes.
| Meas. range |
0 to +3000 ppm SO2 |
| Accuracy ±1 digit |
±5% of mv (+400 to +3000 ppm SO2) ±20 ppm SO2 (0 to +400 ppm SO2) |
| Resolution | 1 ppm SO2 |
| Reaction Time | 80 s |
| Dimensions | 216 x 68 x 47 mm |
| Weight |
500 g |
| Operating Temperature |
+4 to +45 °C |
| Storage Temperature | -20 to +50 °C |
| Battery Type | 4 AA batteries |
| Battery Life | 4 h |
| Material/Housing | ABS |
| Power Supply |
Mains unit |
| Voltage | 115/230 V / 50/60 Hz |
| Display | LCD, 2 lines |
| Warranty | Measuring instrument: 2 years (excluding working parts, e.g. gas sensors, ...) Gas sensors: 6 months Power supply: Battery or mains unit |
testo 325-I COhigh [O2]
The testo 325-I COhigh [O2] is your step to affordable flue gas analysis. Easy handling and low costs make it the ideal portable partner for
The readings are displayed constantly on the display for as long as the pump is running.
| CO | O2 | Type K (NiCr-Ni) | |
| Meas. Range |
0 to 7 Vol. % | 0 ... 21 Vol. % | -40 to +1000 °C |
| Accuracy ±1 digit |
±40 ppm (0 to 0.08 Vol. %) ±5% of mv (0.08 to 0.2 Vol. %) ±10% of mv (0.2 to 7 Vol. %) |
±0.2 Vol. % | ±0.5 °C (-40 to +99.9 °C) ±0.5 % of mv (+100 to +1000 °C) |
| Resolution | 0.001 Vol. % | 0.1 Vol. % | 0.1 °C |
| Oper. temp. | -5 to +45 °C | Storage temp. | -20 to +50 °C |
| Warranty | Meas. instr.: 2 years (excluding wear parts, e.g. gas sensors, ...); O sensor: 1.5 years; CO sensor: 1 year | ||
testo 325-2 / 325-3
The testo 325-2 and -3 instruments offer the standard functions of flue gas analysis for the basic adjustment of oil and gas burners.
testo 325-2 measures O2 in flue gas, flue draught and calculates flue gas loss and efficiency.
testo 325-3 measures the CO level (up to 2000 ppm), draught and gas flow pressure.
testo 325 M / 325 XL
testo 325 M and XL instruments supply all important parameters(O2, CO, °C) at a glance.
They enable differential temperature and differential pressure measurements (40/200 hPa switchable) and fulfill all the requirements for the adjustment, maintenance and servicing of gas and clean oil burners (CO to 4000 ppm).
| testo 325-2/-3 | testo 325 M | testo 325 XL | |
| Temperature measurement |
|||
| Meas. range |
-40 to +600 °C | -40 to +600 °C | -40 to +600 °C |
| Draught/Pressure measurement |
|||
| delta P1 | ±40 hPa | ±40 hPa | ±40 hPa |
| delta P2 | ±200 hPa | ±200 hPa | |
| Efficiency measurement (Eta) |
|||
| Meas. range |
0 to 120 % | 0 to 120 % | 0 to 120 % |
| Flue gas loss (qA) | |||
| Meas. range | 0 to 99.9% qA | 0 to 99.9% qA | 0 to 99.9% qA |
| O2 measurement | |||
| Meas. range | 0 to 21 Vol. % O2 | 0 to 21 Vol. % O2 | 0 to 21 Vol. % O2 |
| CO2 measurement |
|||
| Display range | 0 to CO2max | 0 to CO2max | 0 to CO2max |
| CO measurement | LCD, 2 lines | ||
| Meas. range | 0 to 2000 ppm | 0 to 4000 ppm | 0 to 4000 ppm |