GASTECH News ›› 

Toxi Pro

ToxiProToxiPro

You should never compromise on safety. The new improved ToxiPro has three visual alarm windows for increased worker safety. 

Even better, each alarm window comes standard with both high visibility yellow and red alarm LEDs. In a warning condition, the yellow lights will flash and the lights in all three windows will chase. In a danger condition, the red LEDs will flash and the lights in all three windows will chase. 

 

Plus, the improved ToxiPro has an audible alarm that is 10% louder than previous models! It has many alarm features, including an optional vibrating alarm and sound pattern and set points which are now fully user customizable.

 

 

SPECIFICATIONS

Instrument Type

Single-sensor gas detector, replaceable battery and sensor

Dimensions

3.33" x 2.19" x 1.16" (8.44 cm x 5.56 cm x 2.95 cm)

Weight

3.5 oz (110 grams)

Gas Sensors Available

O2, CO, NH3, NO2, H2S, CO-H, Cl2, HCN, SO2, PH3

Sensor Type

Electrochemical toxic gas sensor or Galvanic oxygen sensor

Alarms

Warning, Danger, TWA (if enabled) and STEL (if enabled)

Audible Alarm

Loud two tone alarm rated at 100dB at 10 cm

Vibrating Alarm

Optional

Visual Alarm

Three alarm windows with high visibility yellow and red alarm LEDs that chase

Low Battery Alarm

Standard

Display Backlight

Activates with button or alarm

Controls

One button operation, including automatic calibration

Clip

Alligator clip standard

Built-in Event Logger

Stores latest 20 events, including sensor type, max reading, average reading, start time and stop time

Black Box DataRecorder

Standard

Readouts

Continuous real-time gas readings, peak, STEL (if enabled), TWA (if enabled) and time of day readings

Replaceable Battery

Up to 9,000 hour battery life

Housing

Compact and rugged, clear polycarbonate with TPE overmold

Durability (IP Rating)

Water and Dust Rating IP65/IP67 (standard housing),

 

IP66/IP67 (Plastite housing)

Standard Accessories Included

Calibration adapter, tubing, operator's guide and quick reference guide

Datalogger upgrade optional

Approx. 135 hrs. @ 1 min. interval (Interval can be changed with optional BioTrak software, IrDA required)

Automatic Docking Station Available

Works with the Biosystems IQ Express Single-Gas. Dock for automatic bump testing, calibration, instrument performance testing and record keeping

Safety Certifications

c-UL-us Classified for Class I, Div. 1, Group A, B, C, D T4 | UL Classified for Class II, Div. 1, Group E, F, G | CSA Classified for Class I, Div 1, Group A,B,C,D T4 | CSA Classified for Class II, Div 1, Group E,F,G | ATEX (DEMKO) EEx ia IIC T4 | IECEx Ex ia IIC T4 | CE Mark | CQST (China) Ex ia IIC T4 | Conforms to IEC 61000-4-3 (10 V/m) for RF Immunity

AVAILABLE MODELS

Part Number
Type
72-8017-XX Standard with datalogging and vibrating alarm
 *Please note that "XX" in part number denotes gas type (eg. "CO").
 

DOWNLOADS

 

RELEVANT LINKS